E41-257 · Cylinder and Hydraulic Selection · Long-Distance Pneumatic Supply · ★★★
A pneumatic device 50 m from the source drops from 0.6 MPa to 0.35 MPa under load and cannot move it. Devices near the source are normal (0.58 MPa).
The supply line uses Φ8×1 mm nylon tube (6 mm ID), length 50 m, total flow about 500 L/min (ANR, 3 cylinders acting together). Line velocity v = Q/A = 0.0083/(π×0.003²) = 294 m/s (grossly over the recommended ≤15 m/s). Friction drop ΔP = λ×L/D×ρ×v²/2 = 0.02×50/0.006×1.2×294²/2 ≈ 0.02×8333×1.2×43218 ≈ 86.4×10⁵ Pa = 8.64 MPa? That is wrong. Correct formula: ΔP = λ×L/D×ρ×v²/2×10⁻⁵. Using the actual formula: Q = 500 L/min = 0.0083 m³/s, v = Q/A = 0.0083/(π×0.003²) = 294 m/s, ΔP = 0.02×50/0.006×1.2×294²/2 ≈ 0.86 MPa. The actual end pressure drops from 0.6 MPa to 0.35 MPa (drop 0.25 MPa), close to the calculation.
① Pneumatic line velocity should be ≤15 m/s (compressed air)\n② Pipe-size check: d = √(4×Q/(π×v)) = √(4×0.0083/(3.14×15)) = 0.0266 m = 26.6 mm\n③ Upgrade pipe size: Φ8 → Φ28 mm (20 mm ID, velocity drops to 26 m/s, still high but usable)\n④ Or install an air receiver at the equipment end (to buffer flow peaks)\n⑤ Shorten the supply distance: place the source near the equipment (≤20 m)