E41-259 · Cylinder and Hydraulic Selection · New Hydraulic-System Air Bleeding · ★★★
During commissioning of the newly installed hydraulic system, the cylinder exhibits stick-slip crawl at low pressure, with uneven speed and failed precise positioning.
After installation the hydraulic system was not fully bled; the oil contains about 3% (volume fraction) air. Air exists as tiny bubbles (0.1~0.5 mm diameter); the effective bulk modulus K_eff = K_oil/(1+V_air/V_oil) = 1400/(1+0.03) ≈ 1359 MPa, a drop of about 3% - not significant by itself. But on the low-pressure side (return chamber) dissolved air comes out of solution at low pressure, forming large bubbles that cavitate at the throttle orifice and cause flow pulsation. Meanwhile the bubbles' compressibility gives the cylinder elastic lag on reversal, showing as low-speed crawl. After about 2 h of operation the bubbles gradually vent and the crawl disappears.
① A newly installed hydraulic system must be fully bled (bleed valves at the highest point of every line)\n② Bleeding method: run at low pressure (0.5 MPa) and stroke the piston full travel 5~10 times\n③ Provide a vent on the power-unit tank (return line submerged below the oil surface to prevent air entrainment)\n④ Fit bleed valves on the cylinders (at the highest point of the barrel)\n⑤ Use an anti-foam additive (silicone-based defoamer to accelerate bubble coalescence and rise)
FT_32_Hydraulic System Design