E41-263 · Cylinder and Hydraulic Selection · Hydraulic-Press Relief-Valve Setting · ★★★★
During pressing the hydraulic press reaches 35 MPa (design pressure 25 MPa); the hydraulic line bursts and oil sprays out.
The main relief valve setting was turned up to 35 MPa (factory setting 25 MPa), exceeding the rated pressure of lines and components. The hydraulic line is seamless steel pipe (Φ28×4 mm, 20# steel), working pressure 25 MPa, test pressure 31.5 MPa, burst pressure about 62 MPa. 35 MPa exceeds the test pressure but is below burst, so it should not burst in principle. But the relief valve is already fully open at 35 MPa and the pump keeps supplying (a constant-pressure variable pump destrokes once pressure reaches the setting), so system pressure stays at 35 MPa. One line at an elbow (cold bend R=1.5D, wall thinned about 8%) bears 35 MPa; fatigue cracks grow on the elbow outer arc and it bursts after about 200 cycles.
① Relief-valve set pressure must be ≤1.1× the system rated pressure\n② After setting, lock the adjusting nut + lead seal (prevent accidental adjustment)\n③ Line elbows should be hot-bent (R≥3D, wall thinning ≤5%)\n④ Add a pressure sensor + over-pressure alarm in the system (>27.5 MPa alarm and stop)\n⑤ Periodically calibrate the relief valve (annually, on a test bench)