Knowledge Base › Selection Error Cases › Hydraulic-System Return-Line Filter Clogging Causing Pump Cavitation (Newly Installed Hydraulic System)

Hydraulic-System Return-Line Filter Clogging Causing Pump Cavitation (Newly Installed Hydraulic System)

E41-270 · Cylinder and Hydraulic Selection · Newly-Installed-System Return Filtration · ★★★

Problem Description

During commissioning of the newly installed hydraulic system the pump emits irregular clicking sounds and the oil contains many bubbles. Disassembly inspection found the return-line filter completely clogged, so the pump struggles to draw oil and cavitation occurs.

Root Cause

Large amounts of welding slag remain in the piping of the new system (pipes were not acid-cleaned when welded); after start-up the slag circulates with the oil and is captured by the return-line filter. The return filter has 10 μm accuracy; slag particles of 50~200 μm are trapped on the element surface. After 2 h the element is completely clogged and the return backpressure rises from 0.05 MPa to 0.5 MPa (the return filter has a bypass valve set at 0.35 MPa); the bypass opens and unfiltered oil flows directly into the tank, so the slag keeps circulating. Meanwhile the high-pressure-side filter also clogs (the pump-outlet high-pressure filter has a contamination indicator, in the red zone), but the operator ignores the red indication. The pump runs under high inlet vacuum and cavitates (gas cavitation); metal fatigue develops inside the pump body and the vanes fracture.

Corrective Solution

① New piping must be acid-cleaned (remove welding slag and scale)\n② On first run, install a temporary strainer (60 mesh) upstream of the return filter\n③ Replace the permanent filter element after 24 h of operation\n④ Watch the filter contamination indicator (replace element immediately in red zone)\n⑤ Install a vacuum gauge at the pump inlet (alarm at vacuum > 0.03 MPa)

Checklist

Reference

FT_32_Hydraulic System Design

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL