E41-272 · Cylinder and Hydraulic Selection · Hydraulic-Clamp Accumulator · ★★★
During pressure holding the hydraulic clamp pressure drops slowly, from 15 MPa to 12 MPa within 30 min. Inspection found the accumulator precharge pressure incorrectly set.
The accumulator (bladder type, 10 L volume) has its precharge pressure set at 12 MPa (working pressure 15 MPa). The optimal precharge pressure P_gas = (0.6~0.85)×P_work = 0.7×15 = 10.5 MPa. A precharge of 12 MPa is too high (equals 0.8×15); the bladder has insufficient compression after charging, so the accumulator only starts releasing oil when system pressure drops below 12 MPa. During holding, when system leakage drops pressure from 15 MPa to 12 MPa before the accumulator supplements, the pressure has already fallen 3 MPa (20%), exceeding the clamp's allowable ±1 MPa fluctuation. With the correct precharge P_gas = 10.5 MPa, the accumulator can supplement oil throughout the entire 15→12 MPa drop, keeping pressure stable.
① Accumulator precharge pressure P_gas = (0.6~0.85)×P_work (take lower limit 0.6 for holding)\n② This example: P_gas = 0.6×15 = 9 MPa\n③ Check precharge pressure monthly (measure at gas valve with pressure gauge)\n④ When bladder ages and precharge drops (about 0.1 MPa/month), replenish gas promptly\n⑤ Mount accumulator as close as possible to the holding cylinder (reduce line-volume loss)
FT_32_Hydraulic System Design