E41-275 · Cylinder and Hydraulic Selection · Vertical-Lift Cylinder Piston-Rod Fracture · ★★★★
A vertically mounted cylinder lifting a 200 kg load fractured at the top thread relief groove of the piston rod, and the load fell. There are rust traces at the relief groove.
The relief groove (groove-bottom radius R0.3 mm) at the piston-rod end thread (M16×1.5) is a stress-concentration point. The piston rod bears tensile load (when vertically lifting, 200 kg load weight + acceleration inertia). Rated tensile force F = mg + ma = 200×9.8 + 200×2 = 2360 N. Nominal stress at relief groove σ_nom = F/A = 2360/(π×0.007²) ≈ 15.3 MPa. Stress concentration factor Kt ≈ 3.0 (sharp relief groove R0.3 mm → d/D = 14/16 = 0.875 → Kt ≈ 3.0). Peak stress σ_peak = Kt×σ_nom = 45.9 MPa, far below the material fatigue limit (σ-1 ≈ 300 MPa), so static strength is safe. But the relief groove is in a humid environment (rinse water + cutting fluid), and surface rust forms (pit depth about 0.1 mm). The stress concentration factor at the pit bottom further increases to Kt_total ≈ 5, peak stress ≈ 76.5 MPa. Under alternating load (once per work cycle) a fatigue crack initiates at the pit bottom and fractures after about 10⁵ cycles.
① Relief-groove fillet radius R ≥ 1 mm (reduce stress concentration)\n② Chrome-plate relief groove for rust proofing (coating 15 μm)\n③ Or eliminate relief groove (use rolled thread instead of cut thread)\n④ Add anti-fall device to vertical-lift cylinder (safety valve or mechanical lock)\n⑤ Periodic crack detection (magnetic particle inspection, every 6 months)
FT_31_Pneumatic System Design