E41-420 · Cylinder and Hydraulic Selection · Pneumatic Quick-Coupler Leakage · ★★★
The pneumatic system loses pressure from 0.6 MPa to 0.1 MPa after 8 h of equipment shutdown (cannot hold pressure), and the compressor starts frequently each day. Inspection found 3 leaking quick couplers.
The pneumatic system uses quick couplers (SMC PC series) to connect air tubes; the internal seal (NBR) of a quick coupler hardens after 2 years of use (hardness from Shore A70 to A85), and the seal lip loses elasticity. In the shut-down state the seal cannot fully block the internal one-way valve, and compressed air slowly leaks through the seal gap. A single quick coupler leaks about 0.5 L/min (ANR) @ 0.6 MPa; 3 couplers leak 1.5 L/min. Over 8 h shutdown the total leakage is about 720 L (≈0.72 m³), equivalent to the air tank (volume 1 m³) pressure dropping from 0.6 MPa to 0.1 MPa. Each time the compressor starts it must replenish about 0.5 m³ of compressed air; the daily start frequency rises from normal 5 times/day to 15 times/day (frequent start-stop increases energy consumption about 30%).
① Replace quick-coupler seal periodically (every 2 years)\n② Upgrade seal material: NBR → FKM (fluoroelastomer, 3× life)\n③ Close air-supply valve when equipment shuts down (cut supply, reduce shutdown leakage)\n④ Perform air-tightness test on line (0.6 MPa hold 30 min, pressure drop ≤ 0.01 MPa)\n⑤ Replace leaking quick coupler promptly when found (soap-water leak detection)
FT_31_Pneumatic System Design