E41-425 · Cylinder and Hydraulic Selection · Hydraulic-Station Return-Oil Foam · ★★★
After 1 h of operation a newly installed hydraulic station produces large amounts of foam in the tank, and foam overflows from the filler port. Inspection found the return-pipe outlet is above the tank oil surface (about 200 mm above).
The hydraulic-system return-pipe outlet should be immersed at least 100 mm below the tank oil surface (to prevent return oil from impacting the surface and generating bubbles). During installation the return-pipe outlet was 200 mm above the oil surface; the return oil (flow 100 L/min, velocity 3 m/s) impacts the oil surface from a height, entraining large amounts of air (about 5% by volume). Air forms tiny bubbles in the oil (diameter 0.1~0.5 mm); the bubbles float up in the tank forming a foam layer (thickness about 50 mm). Air in the foam is drawn into the pump, causing pump cavitation (increased noise, intensified vibration). Meanwhile oil containing bubbles has greater compressibility (bulk modulus drops from 1400 MPa to about 1000 MPa), so the hydraulic system responds more slowly and the actuator moves sluggishly.
① Return-pipe outlet should be ≥ 100 mm below oil surface (≥ 50 mm above tank bottom)\n② Cut return-pipe outlet at 45° bevel (facing tank wall, reduce impact)\n③ Install baffle in tank (defoaming baffle, extend oil residence time in tank)\n④ Add defoamer (silicone-oil based, dosage 0.001~0.005%)\n⑤ Add diffuser to return pipe (reduce velocity, lower impact)