E41-428 · Cylinder and Hydraulic Selection · Pneumatic Branch-Line Pressure Loss · ★★★
A pneumatic system branches a Φ8 mm × 10 m section from the main line (Φ28 mm) to supply one cylinder (bore Φ80 mm, stroke 500 mm); the cylinder moves slowly (speed only 60% of design).
The cylinder bore is Φ80 mm, stroke 500 mm; single-cycle air consumption V = A×L = π×0.04²×0.5 = 0.0025 m³ = 2.5 L (ANR). Required action time 0.5 s gives required flow Q = V/t = 2.5/0.5 = 5 L/s = 300 L/min (ANR). The branch line is Φ8×1 mm (6 mm ID), 10 m long; the line velocity v = Q/A = 0.005/(π×0.003²) ≈ 177 m/s (severely over the recommended ≤ 15 m/s). Friction pressure drop ΔP = λ×L/D×ρ×v²/2 = 0.02×10/0.006×1.2×177²/2 ≈ 0.02×1667×1.2×15665 ≈ 626000 Pa ≈ 0.63 MPa. With supply pressure 0.6 MPa, subtracting the 0.63 MPa drop gives a negative end pressure; actual pressure falls to about 0.1 MPa (when flow is insufficient the drop cannot exceed supply pressure). At 0.1 MPa the cylinder thrust F = P×A = 0.1×10⁶×π×0.04² ≈ 502 N, only 17% of the design thrust (3016 N at 0.6 MPa); the cylinder cannot move the load or moves extremely slowly.
① Pneumatic branch-line diameter check: velocity ≤ 15 m/s\n② Branch-line diameter d = √(4×Q/(π×v)) = √(4×0.005/(π×15)) ≈ 0.0206 m = 20.6 mm\n③ Φ8 tube must be upgraded to Φ22×2 mm (18 mm ID, velocity drops to 20 m/s)\n④ Or install air receiver near cylinder (buffer supply shortfall, volume ≥ 5× single-cycle consumption)\n⑤ Shorten branch-line length (place main line close to equipment, reduce branch length)
FT_31_Pneumatic System Design