Problem Description

During commissioning of a newly installed hydraulic system the pump emits a harsh noise (cavitation noise); disassembly found the suction filter completely clogged, with pump-inlet vacuum reaching 0.05 MPa.

Root Cause

Welding slag remained in the suction piping of the new hydraulic system (pipes not acid-cleaned when welded); after the first start-up the slag flows with the oil to the suction filter (100 μm accuracy) and is trapped. After only 30 min of operation, slag accumulates on the element surface (about 1 mm thick) and the effective filtration area drops about 90%. The filter differential rises from 0.005 MPa to 0.05 MPa (inlet vacuum 0.05 MPa). At 0.05 MPa inlet vacuum, dissolved air in the oil (about 5% by volume) comes out of solution under low pressure, forming cavitation. Cavitation bubbles collapse in the pump high-pressure zone, generating impact (local pressure up to 1000 MPa) that strikes the pump metal surface and produces cavitation noise. After 30 min, honeycomb cavitation pits (depth about 0.1 mm) appear on the pump surface.

Corrective Solution

① New hydraulic-system piping must be acid-cleaned (remove welding slag and scale)\n② On first run, install a temporary strainer before the suction filter (60 mesh, remove after 24 h)\n③ Add vacuum gauge to suction filter (alarm at vacuum > 0.03 MPa)\n④ Increase pump-inlet pipe diameter: suction velocity ≤ 1.5 m/s (reduce inlet pressure loss)\n⑤ Tank oil level should be ≥ 500 mm above pump inlet (use head difference to supply oil)

Checklist

Reference

FT_32_Hydraulic System Design

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »