E41-433 · Cylinder and Hydraulic Selection · Long-Stroke-Cylinder Piston-Rod Buckling · ★★★★
A long-stroke hydraulic cylinder (bore Φ100 mm, stroke 3000 mm, piston-rod diameter Φ45 mm) buckles and sticks when horizontally lifting a 20 kN load.
Piston-rod length L = 3000 mm, diameter d = 45 mm, slenderness ratio L/d = 66.7 (recommended ≤ 50). When horizontally lifting, the rod bears axial compression F = 20000 N. Column buckling critical load P_cr = π²×E×I/(L_e²); corrected: I = π×d⁴/64 = 3.14×0.045⁴/64 ≈ 2.01×10⁻⁷ m⁴, L_e = 2×L = 6000 mm (one end fixed, one free), P_cr = π²×206×10⁹×2.01×10⁻⁷/36 ≈ 22612 N ≈ 22.6 kN. Actual load F = 20 kN < P_cr = 22.6 kN, safety factor 1.13 (recommended ≥ 3). The safety factor is insufficient, so it buckles under slight overload or impact. In actual operation, by near stroke end the rod already shows about 0.5 mm bending deflection, causing the rod to rub the cylinder end cover (one-sided contact), increasing motion resistance 5× and sticking the cylinder.
① Long-stroke hydraulic-cylinder piston-rod column-stability check: P_cr ≥ F×SF (SF ≥ 3)\n② This example needs larger piston-rod diameter: 45 → 63 mm (P_cr increases 4×, SF ≈ 4.5)\n③ Or shorten stroke: 3000 → 2000 mm (L_e from 6000 to 4000 mm, P_cr increases 2.25×)\n④ Add guide rail (shares axial load, eliminates column-buckling risk)\n⑤ Or use double-rod cylinder (both ends fixed, buckling length halved)
FT_32_Hydraulic System Design