E41-449 · Sensor Electrical Selection · Equipment Deformation Causing Optical-Path Misalignment · ★★★★
The through-beam photoelectric sensor on large equipment (8m long) frequently misses detections after the equipment warms up. The optical path aligned in the cold state shifts about 5mm after warm-up.
The emitter and receiver of the through-beam photoelectric sensor are mounted at the two ends of the equipment (8m apart). After operation the equipment undergoes thermal expansion (steel structure temperature rise 20℃, expansion ΔL=α×L×ΔT=12×10⁻⁶×8000×20≈1.9mm); the two ends expand differently (one end rises 30℃ and the other 10℃, temperature difference 20℃, expansion difference Δ=12×10⁻⁶×8000×20=1.9mm). The relative position of emitter and receiver shifts about 1.9mm. The sensor's spot diameter is about 3mm (laser) and the receiver window is 5mm wide; a 1.9mm shift moves the spot across the receiver window and drops the light intensity from 100% to about 70%, which still works. The actual shift is 5mm (besides thermal expansion, the equipment foundation settles slightly by about 3mm), so only about 30% of the spot falls on the receiver window and the light intensity is too low, making the sensor output unstable (intermittent on/off).
① The mounting brackets for long-distance through-beam photoelectric sensors should be adjustable (adjustment range ±10mm)\n② Mount the emitter/receiver on the same side of the equipment (same temperature zone, equal thermal expansion)\n③ Or use a fiber-optic sensor (the cable is fixed, unaffected by thermal deformation of the equipment)\n④ Use a wide-angle receiver (acceptance angle ±5°, less sensitive to optical-path alignment)\n⑤ Recalibrate the sensor optical path after the equipment warms up (hot-state calibration)
FT_33_Sensor Selection Guide