E41-456 · Sensor Electrical Selection · Position Sensor and Limit Interference · ★★★★★
When the CNC machine's Z axis over-travels, the position sensor (linear encoder) is struck and damaged by the mechanical limit; the readhead rubs against the scale and is damaged, with a replacement cost of about 5000 yuan.
The linear encoder (accuracy ±3μm/m) is mounted on the side of the Z axis, with the readhead fixed to the slide. The Z axis's soft limit is set at ±300mm and the hard limit (mechanical stop) at ±310mm. The servo drive decelerates and stops at the soft limit, but occasionally, due to a drive fault or wrong parameter, the Z axis cannot stop in time and hits the hard limit at 10m/min. At the instant of impact (deceleration time about 10ms), the slide's inertial displacement is about 1.7mm (10m/min=0.167m/s, 0.167×0.01=0.00167m=1.7mm). The mounting clearance between the readhead and the scale is only 1mm; during impact the readhead contacts the scale and slides relative to it (about 0.7mm), scratching the scanning grating at the readhead's bottom (glass, 0.5mm thick) beyond repair, requiring replacement of the entire readhead. The mechanical limit has no buffer, so the impact force is transmitted directly to the linear encoder.
① A hydraulic buffer must be fitted in front of the mechanical limit (absorbing impact energy, stroke ≥10mm)\n② The safety distance between the position sensor and the mechanical limit should be ≥ sensor mounting clearance + buffer stroke + safety margin\n③ Add an over-travel protection switch (a hardware limit independent of the servo system, directly cutting off the power supply)\n④ Use an impact-resistant linear encoder (readhead with a slide-protection design that springs away on impact instead of being scratched)\n⑤ Or use a magnetic encoder (head-to-scale clearance ≥1mm, and the head can tolerate some friction)
FT_33_Sensor Selection Guide