E41-114 · Other Selection · Hydraulic Line NPT Threaded Fitting · ★★
An NPT tapered pipe thread fitting on a hydraulic system (working pressure 25MPa) leaked while holding pressure, and it still leaked after retightening. Wrapping it with PTFE tape did not solve the problem.
An NPT tapered pipe thread (1/2"-14NPT) relies on an interference fit of the tapered thread surfaces to seal, but the thread machining tolerance is large (major diameter deviation of the external thread ±0.2mm) and the fit clearance can reach 0.1mm. When ordinary PTFE tape (0.1mm thick) is wrapped on it, the tape is extruded out of the thread clearance at a high pressure of 25MPa and the seal fails. The correct practice is to use an anaerobic pipe thread sealant (such as Loctite 567); the anaerobic adhesive cures within the thread clearance (anaerobic curing, curing once air is excluded), with a fill rate up to 100%, and withstands 35MPa. PTFE tape is only suitable for low pressure (≤ 10MPa) and gas lines.
① PTFE tape sealing is strictly prohibited on hydraulic lines (≥ 10MPa)
② Medium- and high-pressure lines should use an anaerobic pipe thread sealant (withstands ≥ 35MPa)
③ Application procedure: apply the sealant over 3 turns of the external thread (leave one pitch blank at the end)
④ Cure time: fully cured in 24h at 25℃ (reaches service strength in 4h)
⑤ Or use an O-ring sealed fitting (SAE/ISO 6149, a more reliable seal)
FT_Machine Design Handbook