E41-296 · Other Selection · Heavy-Duty Transmission Shaft Key Connection · ★★★★
The parallel key connection on the crusher drive shaft (Φ80mm) failed under heavy shock load; the keyway was crushed and deformed (rolled round) and could no longer transmit torque.
The keyed joint transmits a torque T=5000Nm with a key size of 22×14×80mm (parallel key). Key bearing area A=h/2×L=7×80=560mm². Bearing force F=T/(d/2)=5000/0.04=125kN. Bearing stress σ_p=F/A=125000/560≈223MPa. The key material is 45 steel (σ_s=355MPa), so 223MPa is within the safe range. However, the peak impact load T_peak=3×T_nom=15000Nm gives a bearing stress σ_p_peak=3×223=669MPa, far exceeding the material's yield strength. Under repeated impact, the bearing surfaces on both sides of the keyway undergo plastic deformation (rounding), the shaft and hub no longer rotate coaxially, and the keyed joint fails. At the same time, the stress concentration at the bottom of the keyway (fillet R0.4mm) initiates fatigue cracks at the keyway root.
① Check the heavy-duty keyed joint: bearing stress σ_p ≤ [σ_p] (use 1/3 of the allowable value under impact conditions)\n② Increase the key length: 80→120mm (bearing stress reduced by 33%)\n③ Switch to a double key (arranged at 180°, load capacity increased by about 1.5 times)\n④ Or use a splined connection (load capacity is 3 times that of a parallel key, with low stress concentration)\n⑤ Keyless connection (interference fit + clamping sleeve, no keyway stress concentration)