Knowledge Base › Selection Error Cases › Insufficient safety factor in wire-rope selection leading to broken wires (crane hoist)

Insufficient safety factor in wire-rope selection leading to broken wires (crane hoist)

E41-301 · Other Selection · Crane Wire Rope · ★★★★★

Problem Description

After one year of use, the main hoist wire rope of a crane (Φ20mm, 6×37+FC) showed numerous broken wires, with 12 broken wires within one lay length (scrap criterion: broken wires ≥10).

Root Cause

The wire rope has a rated load of 50kN, a diameter of 20mm, and a breaking force of about 177kN (tensile strength grade 1670MPa). The safety factor SF=177/50=3.54 (the M5 duty class requires ≥4.5). The insufficient safety factor caused a relatively high stress level in the wire rope in actual service. The bending stress of the rope on the drum is σ_bend=E×d/D=206000×1/700≈294MPa (wire diameter d≈1mm, drum diameter D=700mm), and adding the tensile stress σ_t=F/A=50000/(π×10²×0.5)≈318MPa (fill factor 0.5) gives a total stress of about 612MPa. With a wire tensile strength of 1670MPa, the fatigue life under combined bending and tensile alternating stress is about 500,000 cycles (about 1500 per day × 365 days ≈ 550,000), consistent with the actual wire breakage after one year. If the safety factor were raised to 6 (a breaking force of 300kN corresponding to rope diameter Φ26mm), the stress would drop by about 40% and the life could be extended beyond 5 years.

Corrective Solution

① Select the wire-rope safety factor by duty class: M5≥4.5, M6≥5.6, M7≥7.1\n② In this case one class higher is needed: M5→M6, rope diameter Φ20→Φ24mm (safety factor 4.9)\n③ Increase the drum diameter: D≥25×d=25×1=25mm→D≥700mm is acceptable, no increase needed\n④ Lubricate the wire rope periodically (to reduce friction and wear between wires)\n⑤ Check the number of broken wires monthly (scrap when broken wires ≥10 within one lay length)

Checklist

Reference

FT_Machine Design Handbook

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »