E41-312 · Other Selection · Hydraulic Hose Fitting Crimping · ★★★★
During pressure holding, the fitting of a high-pressure hose (Φ12.5mm, 31.5MPa) pulled out of the hose, and the high-pressure oil jet injured a person. Inspection found the crimp amount of the crimping ferrule was insufficient.
The hose-fitting crimping process requires the ferrule outer diameter to be compressed from Φ28mm to Φ24.5mm after crimping (crimp amount 12.5%). The actual outer diameter after crimping was Φ26mm (crimp amount only 7.1%); the insufficient crimping force gave a friction force between the ferrule and the hose outer rubber layer of F_friction=μ×P×A=0.3×10×1000≈3000N (P is the radial pressure of the ferrule on the hose after crimping). The axial force of the hose at a working pressure of 31.5MPa is F_axial=P×A=31.5×π×0.00625²≈3860N. The friction force 3000N<3860N, so the fitting was pulled out during pressure holding. The crimp amount was insufficient because of crimping die wear (die diameter increased by 0.3mm) or because the crimping operator did not adjust the crimping parameters per the process card.
① Hose-fitting crimp amount standard: outer diameter after crimping = (outer diameter before crimping - wire diameter) × (1 - crimp rate)\n② Crimp rate: 12~16% for 1/4"~1" hoses\n③ Inspect the crimping die every 5000 cycles (replace when worn out)\n④ After crimping, perform sampling inspection: take 1 hose from each batch for a pressure test (hold at 1.5 times the working pressure for 5min)\n⑤ Operators must be certified, and the process card must be hung next to the crimping machine