E41-774 · Other Selection · Guard Color · ★★
The equipment guard was painted bright yellow (gloss paint), causing visual fatigue and glare for operators working under strong light.
The bright-yellow guard reflectance is about 70% (gloss paint); workshop lighting is 500 Lux, so reflected light = 500×0.7 = 350 Lux, close to the work-surface illumination standard (500 Lux). When operating the equipment the operator gaze shifts frequently between the workpiece (dark, reflectance 10%, 50 Lux) and the guard (bright yellow, 350 Lux), and the pupil constantly adjusts → visual fatigue → lower work efficiency. It should be changed to matte light gray (reflectance 40%, 200 Lux) to reduce visual contrast.
① Recheck all parameters per correct selection specifications
② Confirm that operating loads, environment, and service life all meet design requirements
③ Select reliable brands and appropriate models
④ Verify installation and operating conditions
⑤ Perform periodic inspection and maintenance after commissioning