Knowledge Base › Selection Error Cases › Pump cavitation caused by a return line lacking an anti-siphon device (return line design)

Pump cavitation caused by a return line lacking an anti-siphon device (return line design)

E41-800 · Other Selection · Return Pipe Cavitation · ★★★★

Problem Description

The hydraulic system return pipe (DN25, 5 m long) entered from the top of the tank; after shutdown the oil in the return pipe siphoned back into the tank, so the pump cavitated on next start-up.

Root Cause

The return pipe entered from the top of the tank (pipe mouth 500 mm above the oil level). After shutdown, the oil filling the return pipe siphoned back into the tank through the return filter, cooler, etc. under gravity, leaving a void in the pipe. On next start-up, the pump flow first had to fill the void in the return pipe (about 2.5 L volume); during filling, an air lock formed in the return pipe, hindering system pressure build-up. Meanwhile, the air in the void entered the oil during operation, worsening cavitation. Correct design: the return pipe should extend 200 mm below the tank oil level (submerged return), or an anti-siphon valve (check valve or vacuum-breaker valve) should be installed at the highest point of the return pipe.

Corrective Solution

① Recheck all parameters per correct selection specifications
② Confirm that operating loads, environment, and service life all meet design requirements
③ Select reliable brands and appropriate models
④ Verify installation and operating conditions
⑤ Perform periodic inspection and maintenance after commissioning