The hinges of the equipment access door (steel plate, size 1000×2000×3 mm, weight about 50 kg) sagged 20 mm after 6 months of use, and the door could not close.
The hinge (ordinary butt hinge, two steel plates plus pin, model 125×100×4 mm) has a load capacity of about 30 kg per pair; two pairs total 60 kg > 50 kg. But the door is 2 m high with a hinge spacing of 1.5 m, and the door's weight acting on the hinge pin produces a bending moment M = 50×10/2 = 250 N·m (average per hinge). The shear stress in the hinge pin (Φ8 mm, Q235) is τ = F/A = 25×9.8/(π×0.004²) = 19.5 MPa, giving a safety factor S = 235/19.5 = 12, so it should not fail. The actual sagging came from the hinge-to-frame fixing screws (4 M6 self-tapping screws driven into 2 mm-thick steel plate). Under the weight, the screw holes in the steel plate elongated (from Φ6 mm to Φ6.5 mm), the screws loosened in the holes, and the door sagged.