E41-812 · Other Selection · Low Vibrator Efficiency · ★★★
The hopper pneumatic vibrator (piston type, frequency 50 Hz, amplitude 2 mm) was mounted at the middle of the hopper side wall, so the vibration force could not be effectively transmitted to the material.
The vibrator was mounted on the hopper side wall (500 mm from the bottom); the vibration energy propagated up and down along the side wall. By the vibration attenuation formula, the attenuation rate in the steel plate is about 0.5 dB/m, so over 500 mm the attenuation is about 0.25 dB—almost none—but the vibration direction did not match the material flow direction (vertically downward). The hopper side-wall vibration (horizontal) compacted the material horizontally, which is unfavorable for vertical discharge. Correct installation: the vibrator should be mounted at the hopper bottom (near the discharge outlet) with its vibration direction aligned with the material flow (vertical), or two vibrators should be installed (at different frequencies, to break the material arch).
① Recheck all parameters per correct selection specifications
② Confirm that operating loads, environment, and service life all meet design requirements
③ Select reliable brands and appropriate models
④ Verify installation and operating conditions
⑤ Perform periodic inspection and maintenance after commissioning
FT_Machine Design Handbook