E41-829 · Other Selection · Ladder Handrail Spacing · ★★★
The equipment access ladder (vertical ladder, height 6 m) had a handrail spacing of 500 mm, not meeting the GB 4053.1 requirement (300–400 mm), posing a fall risk.
The handrail spacing of 500 mm exceeds the standard upper limit of 400 mm; a person climbing the ladder must stretch the arms widely to grip the handrails and easily tires and lets go during the long climb (6 m height). Also the rung spacing was 350 mm (GB requires 250–300 mm), also exceeding the standard. The overall ladder failed to meet safety standards and presented a fall hazard.
① Recheck all parameters per correct selection specifications
② Confirm that operating loads, environment, and service life all meet design requirements
③ Select reliable brands and appropriate models
④ Verify installation and operating conditions
⑤ Perform periodic inspection and maintenance after commissioning
FT_Machine Design Handbook