E41-638 · Gear Drive Selection · Large Gearbox Housing Stiffness · ★★★★★
During full-load testing of a large gearbox (output torque 100 kN·m), housing deformation caused gear mesh misalignment, shifting the tooth-surface contact pattern to the tooth end.
The gearbox housing is a welded structure (Q235 steel plate, wall thickness 20 mm) and deformed under the 100 kN·m full load. Finite element analysis showed that the output-shaft bearing seat reached a maximum displacement of 0.15 mm under torque (in the direction of the meshing force). During gear meshing, the gear-shaft center distance changed by 0.08 mm and the parallelism changed by 0.05 mm/100 mm. The gear face width b = 200 mm, and the misalignment factor K_Hβ = 1+(b/d)²×(F_t×K_A/(b×d₁))×C_γ = 1+(200/400)²×(250000×1.5/(200×400))×0.02 ≈ 1.65. The effective face width b_eff = b/K_Hβ = 200/1.65 ≈ 121 mm, a face-width utilization of only 60%. On the misaligned side, the root stress σ_F = σ_F_design×K_Hβ = 120×1.65 = 198 MPa > the allowable value 180 MPa, and fatigue cracks appeared on the misaligned-side gear after about 6000 h.
① A large gearbox housing must undergo finite element stiffness analysis\n② The bearing-seat displacement should be ≤ 0.02 mm (full-load condition)\n③ Welded-housing ribs: add cross-shaped rib plates, with rib height ≥ 3× the wall thickness\n④ Apply crowning to the gear (lead modification 0.03–0.05 mm, to compensate for housing deformation)\n⑤ Increase the wall thickness from 20 mm to 30 mm (stiffness increased 3.4×), or switch to a ductile-iron housing (good damping, high stiffness)