Knowledge Base › Selection Error Cases › Undercutting caused by too few pinion teeth (oil pump)

Undercutting caused by too few pinion teeth (oil pump)

E41-979 · Gear Drive Selection · Gear Pump · ★★★

Problem Description

A gear pump pinion had z = 13 (< 17) and was undercut; the tooth root was weak, noise was high, it leaked, and efficiency was low.

Root Cause

First, the minimum tooth count without undercutting for a standard 20° pressure angle is z_min = 17; z = 13 undercuts and weakens the root transition curve. Second, undercutting raises the root σ_F, making it prone to breakage and noisy. Third, leakage and low efficiency. [Root cause] Too few teeth.

Corrective Solution

① For a 20° pressure angle, the pinion z ≥ 17 (no undercutting), or use profile shift/a 25° pressure angle
② Use positive profile shift to raise z_min
③ Choose a larger z to reduce noise
④ Check for undercutting
⑤ Standard teeth with z < 17 are prohibited
⑥ Root strengthening
⑦ If noise is high, check z

Checklist