E41-991 · Gear Drive Selection · Worm Gear Lift · ★★★
A lift used a single-start worm intended to be self-locking; the lead angle γ>the friction angle ρ, so it lost self-locking and the load slid down, creating a hazard.
First, self-locking requires the lead angle γ<the friction angle ρ (ρ≈3~6°); a single-start worm with a small γ can lock, but in this case γ=7°>ρ and it lost self-locking. Second, with self-locking lost, the load slid down, creating a hazard. Root cause: γ>ρ.
① A self-locking worm must have γ<ρ (single-start, small lead angle)
② Self-locking efficiency η<0.5
③ Add a mechanical brake on lifts for double safety
④ Verify γ and ρ
⑤ Do not rely on self-locking when γ>ρ
⑥ Add a holding brake
⑦ If it slips, check self-locking
FT_Gear Transmission Design