E41-641 · Belt Drive Selection · Fan V-belt Drive · ★★★
After 2 months of service, all the V-belts (type B, 5 belts) on a fan (power 37 kW, speed 1450 rpm) had slipped and burned out; the belts smoked and the pulley grooves turned blue.
Fan belt-drive calculation: power P=37 kW, driver pulley diameter Φ200 mm, driven pulley Φ450 mm, center distance 1000 mm, service factor K_A=1.3 (the fan has shock). The rated power of a single B-type belt at 1450 rpm / Φ200 mm is P_r≈4.5 kW. Five belts transmit 5×4.5=22.5 kW in total. The required transmitted power is 37×1.3=48.1 kW; 22.5 kW < 48.1 kW, so the number of belts is severely insufficient, actually meeting only 47% of the demand. Under severe overload the belts slipped (slip increasing from 2% to over 15%) and friction generated heat (slip power P_slip≈(48.1-22.5)×0.15≈3.8 kW); the belt temperature rose from the normal 60℃ to 150℃ (the thermal-degradation temperature of rubber), the belts smoked → the surface carbonized → the friction coefficient dropped from 0.3 to 0.15 → slippage worsened further → the belts burned out within 2 months. The pulley grooves turned blue from the high friction temperature (about 300℃), an oxidation color, and the grooves wore.
① V-belt number calculation: Z=P×K_A/(P_r×K_L×K_α) (K_L is the length factor, K_α the wrap-angle factor)\n② In this case Z=48.1/(4.5×0.95×0.92)=12.2 belts, so take 13 belts, not 5\n③ When the number of belts is too high (>8), switch to narrow V-belts (SPB type, 7.5 kW per belt, needing only 7 belts)\n④ Or increase the pulley diameter (Φ200→Φ250 mm, raising the per-belt power to 6.0 kW, requiring 8 belts)\n⑤ Multiple belts must be used in matched sets (length difference ≤ 0.15%, to avoid overloading a single belt)