E41-651 · Belt Drive Selection · Heavy-Load Starting Belt Slip · ★★★
On a heavy-duty conveyor (power 45 kW) the belt slipped badly during starting; the motor current surged from 200 A to 450 A (overload), and after three start attempts the belt smoked.
During starting a belt drive must overcome the inertia of the conveyor system (starting torque T_start = 2.5 × T_nominal = 2.5 × 296 = 740 Nm). The required belt tension F_tension = 2 × T_start/(d × μ) = 2 × 740/(0.2 × 0.3) ≈ 24667 N. The total tension of six B-profile belts is only 6 × 250 = 1500 N (250 N per belt), far less than 24667 N. During starting the belt slipped badly in the pulley grooves (slip ratio >50%); the slip power P_slip = T_start × Δω = 740 × (0.5 × 157) ≈ 58 kW, and nearly all of this slip energy turned into heat, raising the belt temperature from 30 ℃ to 180 ℃ (the rubber thermal-decomposition temperature) within 10 s and charring the belt surface. During slipping the motor load dropped (speed fell) and the current slowly decreased from the 450 A starting current, but the overload lasted too long (>10 s), tripping the thermal relay or overheating the motor.
① For heavy-load starting, belt tension must meet the starting-torque requirement\n② The starting tension F_t ≥ 2 × T_start/(d × μ) = 24667 N → six B-profile belts are not feasible\n③ Switch to SPB narrow V-belts (single-belt tension up to 800 N; ten belts give a total tension of 8000 N)\n④ Or increase the number of belts to 24 (but more than 12 belts is not recommended)\n⑤ Switch to narrow V-belts plus a multi-ribbed belt, or to a timing belt (no slip, transmitting the starting torque directly)
FT_Belt & Chain Drive Design