E41-853 · Belt Drive Selection · Assembly-Line Main Drive · ★★★
On an assembly-line main drive (37 kW) six V-belts in the same set were mixed from two batches (batch difference 2 mm); the short belt broke first, the long belts failed in a chain reaction, and the whole line was stopped for 4 hours.
First, the length difference ΔL within a set must be ≤ the elastic elongation δ_e = F_e·L/(E·A); here δ_e = 4000·1.5/(200e6·294e-6) = 0.10 mm while the batch difference of 2 mm ≫ δ_e. Second, the short belt took nearly the full load F_e = 1000·37/15 = 2467 N, exceeding the per-belt F_e_max ≈ 530 N → instantaneous breakage. Third, after the break the long belts took the 2× impact load and also broke. Root cause: mixed batches with unequal lengths.
① Keep a set of belts from the same maker and batch, with a length tolerance ≤ 0.5 mm
② Measure each belt length individually with a belt gauge and match sets before installation
③ Replacements must be made as a whole set; single-belt replacement is forbidden
④ When selecting belts, calculate the per-belt F_e_max and leave a 2× margin
⑤ Mixing batches, or old and new belts, is forbidden
⑥ After installation, bar the drive over and check that all belts are tensioned equally
⑦ Add belt-break monitoring on critical lines
FT_Belt & Chain Drive Design