E41-864 · Belt Drive Selection · Spare-Parts Management · ★★
A plant installed a V-belt that had sat in the spare-parts store for 3 years; it ran for 2 hours before breaking, halting production for half a day while waiting for a replacement.
First, rubber continues to cross-link and suffers ozone aging in storage, losing about 30% of its strength in 3 years (storage aging rate about 10%/year). Second, uncontrolled temperature and humidity in the store accelerated this, causing surface cracking and rusting of the cords. Third, on installation the belt immediately took the design load F_e, and the aged belt's σ_total exceeded its remaining strength → breakage in 2 h. [Root cause] An over-stored belt was used without inspection.
① V-belt storage life ≤ 2 years; belts past this must have their strength tested before installation
② Store away from light, at a controlled 10~25℃, humidity < 70%, off the floor and clear of walls
③ First in, first out (FIFO), with the storage date marked
④ Check for cracking/hardening before installation and run a tensile test on over-stored belts
⑤ Do not store in the open or beside heat sources
⑥ Keep a spare-parts life ledger
⑦ Use belts from a new batch on critical equipment
FT_Belt & Chain Drive Design