E41-868 · Belt Drive Selection · Petrochemical Conveying · ★★★★
A conveyor in a petrochemical area used an ordinary V-belt; friction generated static sparks, triggering a gas alarm and an emergency shutdown.
First, ordinary rubber belt has a volume resistivity ρ_v > 10¹³ Ω·cm, so the charge generated by friction cannot drain away and the surface voltage can reach several thousand volts. Second, if the discharge energy E = ½C·V² exceeds the minimum ignition energy of the combustible gas (e.g., 0.25 mJ for propane) it ignites. Third, the petrochemical area is a hazardous explosive atmosphere, where ordinary belts are prohibited. [Root cause] A static-conductive belt was not used.
① Hazardous explosive atmospheres must use a static-conductive belt (ρ_v < 10⁸ Ω·cm, surface resistance < 10⁹ Ω)
② State the explosion-protection class (e.g., Ex) in the selection, per GB 3836
③ The belt drive system must be reliably grounded (resistance < 10⁶ Ω)
④ Do not use an ordinary high-resistance belt in a flammable/explosive area
⑤ Add a static eliminator/humidification
⑥ Measure the belt surface resistance periodically
⑦ Hot work/energized work in the area requires approval
FT_Belt & Chain Drive Design