E41-652 · Chain Drive Selection · Elevator Chain Fracture · ★★★★★
The bucket-elevator chain (16A, double-strand) broke after eight months of operation; the bucket fell and smashed the casing. The fracture site showed a fatigue crack in the link plate.
Elevator throughput Q = 50 t/h, lift height H = 20 m, chain speed v = 0.5 m/s. The useful circumferential force is F = Q × H × g/(3600 × v) = 50 × 20 × 9.8/(3600 × 0.5) = 5.44 kN. The rated load of a double-strand 16A chain is F_rated = 111 kN (55.5 kN per strand), giving a safety factor S = 111/5.44 = 20.4, which looks extremely high. In reality, however, the following also apply: ① the chain's own weight (about 10 kg/m, total ≈ 20 m × 10 kg/m × 2 = 400 kg → 4 kN); ② the bucket loading impact factor K = 1.5; ③ the additional dynamic load arising because pitch elongation after chain wear causes poor meshing with the sprocket. The actual maximum tension is F_max = F_static + F_dynamic + 4 = 5.44 + 2.72 + 4 = 12.16 kN, giving a safety factor S = 111/12.16 = 9.1. This satisfies the standard (elevators require S ≥ 7). The fracture was caused by link-plate fatigue: each time the link plate meshes with the sprocket it carries an alternating stress (one stress cycle per revolution), and each cycle produces stress concentration at the pin hole. The clearance between the link-plate hole and the pin grew from 0.1 mm to 0.3 mm through wear, and fretting wear initiated a fatigue crack at the hole edge; the crack propagated → the link plate fractured. It failed after about eight months (roughly 2 × 10⁶ cycles).
① Select an elevator-chain safety factor S ≥ 7 (continuous duty)\n② Link-plate material should be 40Mn or 40Cr (quenched and tempered, σ_b ≥ 1000 MPa)\n③ Check the pin-hole bearing stress (σ_p = 2F/(d × L) ≤ [σ_p] = 40 MPa)\n④ Periodically measure chain pitch elongation (elongation ≤ 2%)\n⑤ Use an automatic lubrication system (keeping an oil film between link plate and pin to reduce fretting wear)
FT_Belt & Chain Drive Design