E41-660 · Chain Drive Selection · Conveyor Chain Misalignment · ★★★
The conveyor chain ran to one side, the link plates rubbed against the frame, and the sprocket tooth flanks wore on one side only. Inspection found the tooth-flank wear at the two ends was inconsistent.
The axes of the conveyor's driving and driven sprockets were not parallel (deviation 0.5°/m in the horizontal plane), so the chain skewed to one side in service. The skew angle θ = 0.5°, and over a 3 m conveyor line the lateral chain offset was δ = L × tanθ = 3 × tan0.5° = 0.026 m = 26 mm. The chain shifted 26 mm to one side of the centerline, and the link plates rubbed against the frame side plate (minimum clearance 10 mm). Because of the chain skew the sprocket tooth flanks contacted on one side (tooth width 40 mm, actual contact only about 15 mm wide); the contact area fell by 62.5% and the contact pressure rose 2.7×. After three months a groove about 1 mm deep was worn into the one-sided contact of the sprocket tooth flank. The chain skewed further on the worn sprocket, creating positive feedback. Finally the chain derailed because of the lateral force produced by the skew.
① The parallelism of the driving/driven sprocket axes should be ≤ 0.1 mm/m\n② Adjust with a laser alignment instrument when installing the sprockets (both sprocket tooth flanks in the same plane)\n③ The chain's straightness should be < 10 mm (over a 3 m length)\n④ When the wear difference between the two sides of the sprocket tooth flank exceeds 1 mm, adjust or replace\n⑤ Add chain guides (anti-skew guide strips; fit wear strips on both sides of the frame)