E41-662 · Chain Drive Selection · Chain Failure in Corrosive Environment · ★★★★
A chemical-plant conveyor chain (24A, with a black-oxide surface treatment) used for two months in an environment containing H₂S gas developed severe surface corrosion; the pins seized and the chain could no longer flex.
Black-oxide treatment (Fe₃O₄, 1–2 μm thick) has extremely poor corrosion resistance in a corrosive environment containing H₂S (concentration about 100 ppm). H₂S dissolves in water to form a weak acid (pH 4–5), and the black-oxide layer is dissolved within two weeks, exposing the base metal. The electrochemical corrosion rate in an H₂S environment is about 0.3 mm/year (for carbon steel). After two months the pin diameter fell from Φ12 mm to Φ11.8 mm (0.1 mm corroded off one side) and the bushing bore rose from Φ14 mm to Φ14.2 mm (0.1 mm corroded off one side). The joint clearance grew from 0.5 mm to 0.9 mm. More seriously, the corrosion product (FeS) expands in volume (about 2.5× that of the original iron), creating a wedging pressure between pin and bushing; the joint clearance became filled with corrosion product → the joint seized → the chain could no longer flex → the sprocket could not mesh → the chain was forcibly stretched at the drive sprocket → the link plates fractured.
① Chains in a corrosive environment must use stainless-steel chain (304 or 316L, resistant to H₂S corrosion)\n② Upgrade the surface treatment: black oxide → zinc plating (15 μm) plus passivation (corrosion resistance improved 10×)\n③ Or use nickel-plated chain (electroless nickel plating, 25 μm thick, dense and pore-free)\n④ Clean the chain and apply rust-preventive oil periodically (once a week: clean with solvent, then apply rust-preventive grease)\n⑤ Seal the chain guard (with nitrogen purging to isolate corrosive gas)
FT_Belt & Chain Drive Design