Knowledge Base › Selection Error Cases › Frequent chain breakage caused by a mismatch between the chain and motor power (undersized selection)

Frequent chain breakage caused by a mismatch between the chain and motor power (undersized selection)

E41-670 · Chain Drive Selection · Undersized Chain Selection · ★★★★

Problem Description

A newly designed conveyor (P = 30 kW, chain speed v = 1 m/s) used a 24A single-strand chain, and the chain broke after one week of operation.

Root Cause

The rated power of a 24A single-strand chain (at Z1 = 17 and n = 40 rpm, from the table) is about 15 kW. The power actually to be transmitted is 30 kW (39 kW with a safety factor of 1.3), far above the 15 kW rating. At 30 kW the actual working tension in the chain is F = P/v = 30000/1 = 30000 N. The ultimate tensile load of a 24A single-strand chain is F_lim = 126 kN, giving a safety factor S = 126/30 = 4.2, which is insufficient by the standard (S ≥ 7). More critically, at a tension of 30 kN the hinge bearing stress is σ_p = F/(d×L) = 30000/(12.07×42) = 59.2 MPa (d = pin diameter 12.07 mm, L = bushing length 42 mm), exceeding the allowable bearing stress [σ_p] = 40 MPa. Under this 59.2 MPa bearing stress the contact surfaces of pin and bushing deform plastically, and the hinge clearance grows from 0.1 mm to 0.3 mm, so the chain elongation reaches 1.5% within one week. Wear debris from hinge wear becomes abrasive wear when lubrication is poor, accelerating hinge failure → after about one week the link plate tears at the pin hole → the chain breaks.

Corrective Solution

① Chain selection must follow the rated-power table for the given power and speed (for a life of 10⁷ cycles)\n② Safety factor S ≥ 7 (continuous duty), S ≥ 5 (intermittent duty)\n③ In this case a 24A double-strand chain should be selected (ultimate load 222 kN, S = 222/30 = 7.4)\n④ Or use a 28A single-strand chain (ultimate load 169 kN, S = 169/30 = 5.6, still insufficient → 28A double-strand, S = 11.3)\n⑤ Hinge bearing stress σ_p = F/(d×L) ≤ [σ_p] = 40 MPa

Checklist

Reference

FT_Belt & Chain Drive Design

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL