Knowledge Base › Selection Error Cases › Impact from non-uniform chain speed (VFD start/stop)

Impact from non-uniform chain speed (VFD start/stop)

E41-969 · Chain Drive Selection · VFD Chain Drive · ★★★

Problem Description

A chain driven by a VFD with frequent start/stop took impacts; the pitch changed, the chain broke and the machine shut down.

Root Cause

First, frequent start/stop subjects the chain to an inertia impact F_i = m·a, and the large a exceeds the steady load. Second, the impact fatigues the link plates and changes the pitch. Third, the chain broke. [Root cause] Impact.

Corrective Solution

① Limit the acceleration a for VFD start/stop
② Select the chain on the peak with margin
③ Add a flywheel to clip peaks
④ Select a high-fatigue chain
⑤ Do not start/stop abruptly
⑥ Periodically check the pitch
⑦ Check for impact whenever the chain breaks

Checklist

Reference

FT_Belt & Chain Drive Design

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »