E41-973 · Chain Drive Selection · Chain-Drive Resonance · ★★★★

Problem Description

In a chain drive the excitation frequency approached the chain transverse natural frequency; resonance produced loud noise and breakage and the machine shut down.

Root Cause

First, the chain transverse natural frequency is f_n = (1/2π)√(k/m), and the excitation f = z1·n/60 approached f_n → resonant amplification. Second, the amplitude raised the alternating stress σ_a in the chain and it broke. Third, the machine shut down. [Root cause] Resonance.

Corrective Solution

① The excitation frequency must deviate from the chain natural frequency by more than 20%
② Adjust n or z1 to avoid resonance
③ Increase the chain stiffness k or reduce the span
④ Add damping / tensioning
⑤ Do not run near resonance
⑥ Measure the vibration spectrum
⑦ Check the frequency whenever vibration appears