Knowledge Base › Selection Error Cases › Cavitation caused by an undersized hydraulic pump suction line (excessive noise from the hydraulic power unit)

Cavitation caused by an undersized hydraulic pump suction line (excessive noise from the hydraulic power unit)

E41-671 · Hydraulic Component Selection · Hydraulic Power Unit Pump · ★★★

Problem Description

The hydraulic power unit ran with high noise (85 dB), the pump body vibrated, and large numbers of bubbles were visible in the oil. On teardown, cavitation pits were found on the pump's port plate.

Root Cause

The suction line of pump CB-B63 has an inside diameter of Φ25 mm with a flow velocity of 3.1 m/s (recommended ≤1.5 m/s) and high suction resistance. As the oil temperature rises the oil viscosity falls and the saturated vapor pressure rises, generating bubbles in the suction zone → collapse in the high-pressure zone → cavitation → noise and vibration.

Corrective Solution

① Increase the suction line inside diameter to Φ40 mm (velocity drops to 1.2 m/s)
② Shorten the suction line to under 1 m
③ Use a large-bore suction filter (pressure drop ≤0.005 MPa)
④ Lower the oil temperature below 45℃ (fit a cooler)
⑤ The pump should be installed below the oil level