Knowledge Base › Selection Error Cases › Oil oxidation caused by an undersized hydraulic reservoir

Oil oxidation caused by an undersized hydraulic reservoir

E41-684 · Hydraulic Component Selection · Hydraulic Reservoir Design · ★★★

Problem Description

After 500 h of system operation the oil turned black and the acid value rose from 0.5 to 2.0 mgKOH/g.

Root Cause

The reservoir volume of 100 L against a pump flow of 80 L/min gives a ratio of 1.25 (standard recommendation 3~5 times), so the oil circulated too fast and oxidized more quickly.

Corrective Solution

① Reservoir volume ≥3 times the pump flow
② Fit baffles in the reservoir to lengthen the circulation path
③ Keep the oil temperature ≤60℃

Checklist

Reference

FT_Hydraulic & Pneumatic Design

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »