Knowledge Base › Selection Error Cases › Insufficient output caused by excessive return-line back pressure in the hydraulic system

Insufficient output caused by excessive return-line back pressure in the hydraulic system

E41-686 · Hydraulic Component Selection · Excessive Return-Line Back Pressure · ★★★

Problem Description

The cylinder thrust reached only 70% of the theoretical value, and the return-line pressure was 1.5 MPa (standard <0.5 MPa).

Root Cause

The return line diameter is Φ12 mm giving a flow velocity of 7.4 m/s (recommended ≤2 m/s) and a back pressure of 1.54 MPa.

Corrective Solution

① Size the return line bore so the flow velocity is ≤2 m/s
② Keep the return line as short as possible
③ Do not fit a back-pressure valve unless necessary

Checklist

Reference

FT_Hydraulic & Pneumatic Design

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »