Using Water-Glycol Fire-Resistant Fluid Causing Accelerated Pump Wear

E41-692 · Hydraulic Component Selection · Water-Glycol Hydraulic Fluid · ★★★★

Problem Description

A piston pump on water-glycol dropped volumetric efficiency from 95% to 65% after 6 months.

Root Cause

Water-glycol lubricity is only 50% of mineral oil; the boundary film is thin and friction coefficient rises 5×.

Corrective Solution

① On water-glycol derate the pump 20% (speed ×0.8, pressure ×0.8)
② Choose a water-glycol-rated pump
③ Periodically test water content, holding 35~45%

Checklist

Reference

FT_Hydraulic & Pneumatic Design