E41-995 · Hydraulic Component Selection · Hydraulic Pump Station · ★★★★
In one system the pump displacement q was too small; under load the pressure dropped, the action was weak, the press could not push in, and parts were scrapped.
First, pump flow Q=q·n·η_v; a small q makes Q insufficient, and under load the pressure drop Δp=Q²·R causes outlet pressure to fall. Second, actuator force F=p·A becomes insufficient as p drops. Third, it cannot press in and parts are scrapped. Root cause: undersized displacement.
① Select pump displacement q by the system peak flow Q=q·n·η_v and leave 20% margin
② Verify that the pressure drop under load Δp≤10% of supply pressure
③ Sum the flow when multiple actuators operate in parallel
④ Use a variable displacement pump to adjust flow
⑤ Do not use a small displacement pump to drive large flow
⑥ Provide pressure compensation
⑦ If action is weak, check q immediately