MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
HomeModels
Table of contents

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Knowledge Base › Selection Error Cases › Overpressure Due to Wrong Relief Valve Pressure Setting (Failure)

Overpressure Due to Wrong Relief Valve Pressure Setting (Failure)

E41-997 · Hydraulic Component Selection · Relief Valve · ★★★★

Problem Description

One relief valve was set higher than the actuator pressure rating; pressure buildup burst a pipe, oil sprayed out, and it was a hazard.

Root Cause

First, the relief valve set pressure p_y must be ≤ the allowable system/component pressure; setting it too high causes overpressure. Second, overpressure bursts the pipe and sprays oil, a hazard. Root cause: wrong setting.

Corrective Solution

① Relief valve p_y ≤ component/pipe allowable pressure with 10% margin
② Set p_y according to the pump rated pressure
③ Add a pressure gauge for monitoring
④ Do not overset
⑤ Provide multi-stage relief
⑥ Periodically calibrate the set value
⑦ If burst, check p_y immediately

Checklist

Reference

FT_Hydraulic & Pneumatic Design

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL