E41-1007 · Hydraulic Component Selection · Hydraulic Lines · ★★★

Problem Description

One long narrow line had a large pressure loss Δp, weak force at the end, and slow action.

Root Cause

First, line pressure loss Δp=λ(L/d)(ρv²/2); small d and long L give large Δp. Second, weak and slow at the end. Root cause: small, long lines.

Corrective Solution

① Select pipe diameter by flow Δp=λ(L/d)(ρv²/2), with Δp≤10% of system pressure
② Main lines large diameter, short and straight
③ Control flow velocity at 2–5 m/s
④ Place pumps near actuators
⑤ Do not use long narrow lines
⑥ Check pressure loss
⑦ If weak, check lines immediately

Checklist

Reference