E41-1014 · Hydraulic Component Selection · Hydraulic Energy Saving · ★★★
One system had the relief valve bypassing continuously; energy consumption was high, oil temperature rose, and electricity costs doubled.
First, constant relief bypass sends full pump flow through the relief back to tank; power P=p·Q is entirely dissipated as heat. Second, high oil temperature and doubled electricity cost. Root cause: constant relief bypass.
① Use variable displacement pumps / load-sensing pressure to keep the relief valve closed
② Unloading circuit (unloading at directional valve neutral)
③ Use accumulators to peak-shave and downsize the pump
④ Keep relief flow to a minimum
⑤ Do not allow constant relief bypass
⑥ Provide an energy-saving mode
⑦ If energy consumption is high, check relief bypass immediately