E41-911 · Pneumatic Component Selection · Pneumatic Circuit · ★★★
One pneumatic line omitted the FRL unit; the air supply carried water at pressure directly; cylinders rusted, valves stuck, and there were 5 faults per month.
First, the FRL = filter + regulator + lubricator; without it, water and oil enter cylinders and valves. Second, water causes internal rust and lack of lubrication causes seal dry wear, raising the fault rate 5×. Third, unstable pressure causes output force fluctuation. Root cause: FRL omitted.
① Pneumatic systems must have an FRL unit (filtration ≥40 μm, regulated stable 0.1–0.7 MPa, oil mist lubrication)
② Set the working pressure on the regulator and stabilize it
③ Drain the filter periodically and replace the element quarterly
④ Adjust lubricator mist concentration (drops per cubic meter of air)
⑤ Do not supply directly without FRL
⑥ Add fine filtration in wet environments
⑦ If faults occur frequently, check the FRL immediately
FT_Hydraulic & Pneumatic Design