E41-923 · Pneumatic Component Selection · Air-Hydro Booster Press Fitting · ★★★
One air-hydro booster had the wrong intensification ratio; output was half expected, press fitting fell short, and parts were scrapped.
First, booster output F=p_air·A_air·k (k = intensification ratio); wrong k makes F=half expected. Second, press fitting requires F_req=5 kN, but actual 2.5 kN cannot press in. Third, scrapped. Root cause: wrong intensification ratio.
① Booster output F=p_air·A_air·k; back-calculate k from requirement
② Verify press force F_req and select k and A_air
③ Use oil on the hydraulic side with oil-resistant seals
④ Match stroke/speed to cycle time
⑤ Install a pressure switch to confirm position
⑥ Do not select k wrong
⑦ If it cannot press in, check output immediately
FT_Hydraulic & Pneumatic Design