E41-928 · Pneumatic Component Selection · Pneumatic Servo Positioning · ★★★★
One pneumatic servo used an on/off valve in place of a proportional valve; step positioning overshot ±2 mm and machining was scrapped.
First, pneumatic servo needs a proportional valve to continuously adjust flow for stable speed positioning; an on/off valve only switches → overshoot. Second, gas compressibility makes the position loop low-stiffness; without proportional adjustment overshoot is large. Third, accuracy ±0.5 mm exceeded 4×. Root cause: wrong valve type.
① Pneumatic servo requires a proportional/servo valve for continuous flow adjustment
② Select a high-response proportional valve (frequency response ≥10 Hz)
③ Add a position feedback closed loop (magnetic/optical scale)
④ Gas compressibility requires high gain + feedforward compensation
⑤ Do not use an on/off valve in place of a servo
⑥ Select low-friction cylinders to reduce hysteresis
⑦ If overshooting, check valve type immediately
FT_Hydraulic & Pneumatic Design