Problem Description

One valve's 24 V coil was mistakenly connected to 220 V; it burned instantly, smoked, and the valve died.

Root Cause

First, coil rated voltage must match the supply; 24 V on 220 V raises current I=U/R by 9× and power P=U²/R by 100×. Second, instantaneous overheating burns insulation. Third, valve dead, production stops. Root cause: wrong voltage.

Corrective Solution

① Coil voltage must strictly match supply (24V/220V/110V)
② Verify nameplate voltage before wiring
③ Add fuse / overvoltage protection
④ Label valves of different voltages distinctly
⑤ Do not mix connections
⑥ Check polarity when wiring
⑦ If burned, check voltage immediately