Knowledge Base › Selection Error Cases › High Pneumatic System Energy Use (Continuous Air Consumption)

High Pneumatic System Energy Use (Continuous Air Consumption)

E41-943 · Pneumatic Component Selection · Pneumatic System Energy Saving · ★★

Problem Description

One line's cylinders held pressure by continuous air feed; air use was high, the compressor ran at full load, and electricity cost was high.

Root Cause

First, cylinders still vented air after reaching position; consumption Q=leakage + continuous pressure holding. Second, wasteful consumption keeps the compressor at 100% load and doubles electricity cost. Third, uneconomical. Root cause: continuous-air design.

Corrective Solution

① Cut air / latch on reaching position; do not hold pressure with continuous air
② Use latching valves / double solenoid for holding
③ Leak test (soapy water) to reduce leakage
④ Use air receivers to peak-shave large flow
⑤ Select high-efficiency compressor + VFD
⑥ Do not use continuous-air design
⑦ If energy use is high, check leakage immediately