E41-871 · Seal Component Selection · Pneumatic Directional Valve · ★★★
One pneumatic valve (0.8 MPa) had O-ring compression of only 8%; the valve port leaked slightly, the actuator was sluggish, and line cycle was erratic.
First, compression δ=8%< the dynamic minimum 10%; initial contact stress σ_c=ρ·δ·E is insufficient to seal. Second, working pressure 0.8 MPa needs contact stress σ_c>0.8 MPa; at δ=8%, σ_c=0.6 MPa<0.8 → medium pushes the ring open into a gap and leaks. Third, pneumatic reciprocation shifts the ring out of contact, leaking more. Root cause: insufficient compression.
① Dynamic seal compression ≥10% (static ≥15%); take per standard
② Verify contact stress σ_c >1.2× working pressure
③ Back-calculate groove depth h=d2(1-δ) from wire d2 and δ
④ For low-pressure pneumatics select low hardness (Shore 70) to improve conformity
⑤ Check compression feel / measure groove before assembly
⑥ Do not use δ<10% for dynamic seals
⑦ If slight leakage, check compression immediately
FT_Seal Spring Design